Fabrication of Chitosan-Silver Nanoparticles composite coatings by galvanic deposition for orthopaedic implants

Coating chitosan AgNPs Corrosion Orthopedic implantSettore ING-IND/23 - Chimica Fisica Applicata
researchProduct

Co-deposition and characterization of hydroxyapatite-chitosan and hydroxyapatite-polyvinylacetate coatings on 304 SS for biomedical devices

2019

During the last decades, biomaterials have been deeply studied to fabricate and improve coatings for biomedical devices. Metallic materials, especially in the orthopedic field, represent the most common materials used for different type of devices thanks to their good mechanical properties. Nevertheless, low/medium resistance to corrosion and low osteointegration ability characterizes these materials. To overcome these problems, the use of biocoatings on metals substrate is largely diffused. In fact, biocoatings have a key role to confer biocompatibility features, to inhibit corrosion and thus improve the lifetime of implanted devices. In this work, the attention was focused on Hydroxyapati…

CorrosionChitosanGalvanic depositionOrthopedic implantSettore ING-IND/24 - Principi Di Ingegneria ChimicaSettore ING-IND/23 - Chimica Fisica Applicata304 stainless steelSettore BIO/10 - BiochimicaPolyvinyl acetateSettore ING-IND/34 - Bioingegneria IndustrialeCytocompatibilityHydroxyapatite
researchProduct

Calcium phosphate/polyvinyl acetate coatings on SS304 via galvanic co-deposition for orthopedic implant applications

2021

Abstract In this work, the galvanic deposition method is used to deposit coatings of brushite/hydroxyapatite/polyvinyl acetate on 304 stainless steel. Coatings are obtained at different temperatures and with different sacrificial anodes, consisting of a mixture of brushite and hydroxyapatite. Samples are aged in a simulated body fluid (SBF), where a complete conversion of brushite into hydroxyapatite with a simultaneous change in morphology and wettability occurred. The corrosion tests show that, compared with bare 304, the coating shifts Ecorr to anodic values and reduces icorr Ecorr, and icorr has different values at different aging times due to chemical interactions at the solid/liquid i…

Materials scienceGalvanic anodeCytotoxicitySimulated body fluidPolyvinyl acetate02 engineering and technologyengineering.material010402 general chemistry01 natural sciencesHydroxyapatiteCorrosionchemistry.chemical_compoundCoatingMaterials ChemistryGalvanic cellBrushiteOrthopedic implantsSettore ING-IND/24 - Principi Di Ingegneria ChimicaPolyvinyl acetateSettore ING-IND/34 - Bioingegneria IndustrialeSurfaces and InterfacesGeneral Chemistry021001 nanoscience & nanotechnologyCondensed Matter Physics0104 chemical sciencesSurfaces Coatings and FilmsAnodeCorrosionGalvanic depositionSettore ING-IND/23 - Chimica Fisica ApplicataChemical engineeringchemistryengineering0210 nano-technologySurface and Coatings Technology
researchProduct

Composite Coatings of Chitosan and Silver Nanoparticles Obtained by Galvanic Deposition for Orthopedic Implants

2022

In this work, composite coatings of chitosan and silver nanoparticles were presented as an antibacterial coating for orthopedic implants. Coatings were deposited on AISI 304L using the galvanic deposition method. In galvanic deposition, the difference of the electrochemical redox potential between two metals (the substrate and a sacrificial anode) has the pivotal role in the process. In the coupling of these two metals a spontaneous redox reaction occurs and thus no external power supply is necessary. Using this process, a uniform deposition on the exposed area and a good adherence of the composite coating on the metallic substrate were achieved. Physical-chemical characterizations were car…

Settore ING-IND/24 - Principi Di Ingegneria ChimicaSettore ING-IND/23 - Chimica Fisica ApplicataPolymers and Plastics304L stainless steel Ag nanoparticles chitosan coating corrosion galvanic deposition orthopedic implantSettore ING-IND/17 - Impianti Industriali Meccanicichitosan; Ag nanoparticles; 304L stainless steel; coating; galvanic deposition; corrosion; orthopedic implantSettore ING-IND/34 - Bioingegneria IndustrialeGeneral ChemistryPolymers
researchProduct

Hydroxyapatite/Chitosan/Collagen coatings through galvanic coupling

In this work, the attention was focused on Hydroxyapatite/ Chitosan/Collagen composite as biocoatings for application in orthopaedic devices. Hydroxyapatite was selected for its osteoconductivity due to its chemical structure similar to bones. Collagen has the same function since 90-95% of bone matrix is constituted of collagen fibers. Furthermore, chitosan are largely used yet in medical field (e.g. antibacterial agent or drug deliver) and in this work were used to create a synergic interaction with hydroxyapatite and collagen to increase the strength and bioactivity of coating. Coatings were fabricated by galvanic deposition process that has different advantages an it does not require ext…

Settore ING-IND/24 - Principi Di Ingegneria ChimicaSettore ING-IND/23 - Chimica Fisica ApplicataSettore BIO/10 - BiochimicaSettore ING-IND/34 - Bioingegneria IndustrialeGalvanic deposition hydroxyapatite 304 stainless steel orthopedic implants chitosan collagen corrosion cytocompatibility
researchProduct

Galvanic Deposition of Calcium Phosphate/Bioglass Composite Coating on AISI 316L

2023

Calcium phosphate/Bioglass composite coatings on AISI 316L were investigated with regard to their potential role as a beneficial coating for orthopedic implants. These coatings were realized by the galvanic co-deposition of calcium phosphate compounds and Bioglass particles. A different amount of Bioglass 45S5 was used to study its effect on the performance of the composite coatings. The morphology and chemical composition of the coatings were investigated before and after their aging in simulated body fluid. The coatings uniformly covered the AISI 316L substrate and consisted of a brushite and hydroxyapatite mixture. Both phases were detected using X-ray diffraction and Raman spectroscopy.…

Settore ING-IND/24 - Principi Di Ingegneria ChimicacorrosionSettore ING-IND/23 - Chimica Fisica Applicatagalvanic depositionAISI 316LcoatingcytotoxicityhydroxyapatiteSettore ING-IND/34 - Bioingegneria IndustrialeBioglass 45S5Settore ING-IND/32 - Convertitori Macchine E Azionamenti Elettriciorthopedic implant
researchProduct

Appropriateness in Dentistry: A Survey Discovers Improper Procedures in Oral Medicine and Surgery

2018

Objectives. The aim of this study was to assess appropriateness of diagnostic exams, treatments, and procedures among Italian dental practitioners.Materials and Methods. A questionnaire with multiple responses on topics of dentistry and oral medicine was administered to a sample of 198 Italian dental practitioners. Information on characteristics of the respondents was also collected. Descriptive statistics and multiple correspondence analysis (MCA) were applied. Data were analyzed using R software (version 3.3.2).Results. The survey respondents included Doctors of Medicine (MD) (54/198 = 27%) with or without specialty in dentistry (33% versus 67%), Doctors of Dental Surgery (DDS) (144/198 =…

medicine.medical_specialtyR softwareArticle SubjectOral surgerySpecialtyDentistry03 medical and health sciences0302 clinical medicineMultiple correspondence analysismedicineDentistry oral medicine surgery030212 general & internal medicineMedical prescriptionGeneral DentistryDescriptive statisticsbusiness.industryHealth-care-system Antibiotic-prophylaxis Orthopedic implants Dental procedures Cancer Prevention Management Overuse030206 dentistrylcsh:RK1-715stomatognathic diseaseslcsh:DentistryDental surgerybusinessOral medicineResearch ArticleInternational Journal of Dentistry